OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 12/07/2022 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1375 | 0.98 | 0.99 |
1775 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER | EER |
1400 | 56500 | 14.00 | 11.50 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | NOM CFM | ARI REF # |
Published Date: 12/07/2022 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 29.80 | 29.30 | 29.00 | 28.70 | 4.14 | 4.35 | 4.46 | 4.57 |
7 | 32.80 | 32.20 | 31.90 | 31.60 | 4.16 | 4.37 | 4.48 | 4.59 |
12 | 35.80 | 35.10 | 34.80 | 34.50 | 4.17 | 4.39 | 4.50 | 4.61 |
17 | 38.80 | 38.10 | 37.70 | 37.40 | 4.19 | 4.41 | 4.52 | 4.63 |
22 | 40.40 | 39.70 | 39.30 | 38.90 | 4.19 | 4.41 | 4.52 | 4.63 |
27 | 42.00 | 41.20 | 40.80 | 40.40 | 4.18 | 4.40 | 4.51 | 4.62 |
32 | 43.60 | 42.80 | 42.40 | 42.00 | 4.18 | 4.40 | 4.51 | 4.62 |
37 | 46.60 | 45.70 | 45.30 | 44.90 | 4.20 | 4.42 | 4.53 | 4.64 |
42 | 51.70 | 50.70 | 50.20 | 49.70 | 4.25 | 4.48 | 4.59 | 4.70 |
47 | 56.70 | 55.70 | 55.10 | 54.60 | 4.31 | 4.53 | 4.65 | 4.76 |
52 | 59.70 | 58.60 | 58.00 | 57.50 | 4.33 | 4.55 | 4.67 | 4.78 |
57 | 62.70 | 61.50 | 60.90 | 60.30 | 4.35 | 4.57 | 4.69 | 4.80 |
62 | 65.70 | 64.50 | 63.80 | 63.20 | 4.37 | 4.60 | 4.71 | 4.82 |
67 | 68.70 | 67.40 | 66.70 | 66.10 | 4.38 | 4.62 | 4.73 | 4.85 |
72 | 71.70 | 70.30 | 69.60 | 69.00 | 4.40 | 4.64 | 4.75 | 4.87 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM. | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1750 | 0.99 | 0.98 |
2250 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | COP 17 | HSPF |
1400 | 53500 | 3.70 | 36600 | 2.60 | 8.20 |
A.R.I. Standard Capacity Rating Conditions |
A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |