OD MODEL
4A6H7060A1

ID MODEL
4PXCCU60BS3

FURNACE
S9V2C100U5PSB

NOM CFM
1740

ARI REF #
201804231

Published Date: 05/08/2025

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

< font size="3"> OD AMB
ID WBTOT CAP72757880KW
85
5952.9044.3049.852.9052.904.07
6355.4036.0041.647.0050.704.11
6759.2028.1033.739.2042.904.15
7164.3020.6026.131.6035.304.19
95
5949.8042.8048.249.8049.804.57
6352.2034.7040.245.7049.404.62
6755.8026.8032.437.9041.604.66
7160.5019.2024.830.3034.004.71
105
5946.7041.4045.946.7046.705.07
6349.0033.3038.944.4048.005.12
6752.3025.5031.136.5040.205.17
7156.8018.0023.529.0032.705.22
115
5943.6040.1043.643.6043.605.56
6345.7032.0037.543.0045.705.62
6748.9024.2029.835.3039.005.68
7153.0016.7022.227.7031.405.73

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.< /font>CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
15250.980.99
19501.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEER2EER2
15405450015.2011.50

A.R.I. Standard Capacity Rating Conditions

< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

 

 

OD MODEL
4A6H7060A1

ID MODEL
4PXCCU60BS3

FURNACE
S9V2C100U5PSB

NOM CFM
2000

ARI REF #
201804231

Published Date: 05/08/2025

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
227.4026.9026.6026.404.034.254.364.47
730.7030.1029.8029.504.074.294.404.52
1234.0033.4033.0032.704.114.344.454.57
1737.3036.6036.2035.904.164.394.504.61
2239.2038.5038.1037.804.184.414.524.64
2741.2040.4040.0039.604.204.434.544.66
3243.1042.3041.9041.504.214.454.564.68
3746.4045.5045.1044.704.264.494.614.73
4251.7050.8050.3049.804.344.584.704.82
4757.1056.0055.5055.004.424.674.794.91
5260.4059.3058.7058.104.464.714.844.96
5763.7062.5061.9061.304.514.764.885.01
6267.0065.7065.1064.504.554.814.935.06
6770.3069.0068.3067.704.604.854.985.11
7273.6072.2071.5070.804.644.905.035.16

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.< /font>CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
17500.990.98
22501.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF2
1540545003.60356002.507.50

A.R.I. Standard Capacity Rating Conditions

< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

LOW STAGE

OD MODEL
4A6H7060A1

ID MODEL
4PXCCU60BS3

FURNACE
S9V2C100U5PSB

NOM CFM
1400

ARI REF #
201804231

Published Date: 05/08/2025

COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES

< font size="3"> OD AMB
ID WBTOT CAP72757880KW
75
5941.9033.5037.441.4041.202.22
6344.0027.6031.535.5038.102.24
6747.0021.9025.929.8032.502.26
7151.0016.5020.524.4027.102.28
85
5940.0032.6036.640.0040.002.77
6342.0026.7030.734.6037.302.80
6744.8021.1025.129.0031.602.83
7148.6015.7019.723.6026.202.86
90
5939.1032.2036.239.1039.103.05
6341.0026.3030.334.2036.803.09
6743.8020.7024.728.6031.203.12
7147.5015.3019.323.2025.803.15
95
5938.1031.8035.738.1038.103.33
6340.0025.9029.933.8036.403.37
6742.7020.3024.328.2030.803.40
7146.3014.9018.922.8025.403.44

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.< /font>CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
12250.980.99
15751.021.01

ARI RATING FOR COOLING

CFMCAPACITY (A) TESTSEER2EER2
15404162215.2011.50

A.R.I. Standard Capacity Rating Conditions

< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

 

LOW STAGE

 

 

OD MODEL
4A6H7060A1

ID MODEL
4PXCCU60BS3

FURNACE
S9V2C100U5PSB

NOM CFM
1400

ARI REF #
201804231

Published Date: 05/08/2025

HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE

 TOTAL CAPACITY MBH.TOTAL POWER IN KILOWATTS
OD AMB6070758060707580
2226.8026.3026.0025.803.263.453.543.63
2728.6028.1027.8027.603.243.433.523.62
3230.5029.9029.6029.303.233.423.513.60
3733.3032.7032.4032.003.233.423.513.61
4237.6036.9036.5036.203.263.453.553.64
4741.8041.1040.7040.303.293.483.583.67
5244.7043.8043.4043.003.293.493.583.68
5747.5046.6046.1045.703.303.493.593.68
6250.3049.4048.9048.403.303.493.593.69
6753.1052.1051.6051.103.313.503.593.69
7255.9054.9054.4053.803.313.503.603.69

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

AIR FLOW RATE, CFM.< /font>CAPACITY MULTIPLIERTOTAL POWER MULTIPLIER
12250.990.98
15751.011.03

ARI RATING FOR HEATING

CFMCAPACITY 47COP 47CAPACITY 17COP 17HSPF2
1540545003.60356002.507.50

A.R.I. Standard Capacity Rating Conditions

< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.