OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 05/08/2025 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
< font size="3"> OD AMB |
|
85 |
|
95 |
|
105 |
|
115 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM.< /font> | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1525 | 0.98 | 0.99 |
1950 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER2 | EER2 |
1540 | 54500 | 15.20 | 11.50 |
A.R.I. Standard Capacity Rating Conditions |
< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 05/08/2025 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
2 | 27.40 | 26.90 | 26.60 | 26.40 | 4.03 | 4.25 | 4.36 | 4.47 |
7 | 30.70 | 30.10 | 29.80 | 29.50 | 4.07 | 4.29 | 4.40 | 4.52 |
12 | 34.00 | 33.40 | 33.00 | 32.70 | 4.11 | 4.34 | 4.45 | 4.57 |
17 | 37.30 | 36.60 | 36.20 | 35.90 | 4.16 | 4.39 | 4.50 | 4.61 |
22 | 39.20 | 38.50 | 38.10 | 37.80 | 4.18 | 4.41 | 4.52 | 4.64 |
27 | 41.20 | 40.40 | 40.00 | 39.60 | 4.20 | 4.43 | 4.54 | 4.66 |
32 | 43.10 | 42.30 | 41.90 | 41.50 | 4.21 | 4.45 | 4.56 | 4.68 |
37 | 46.40 | 45.50 | 45.10 | 44.70 | 4.26 | 4.49 | 4.61 | 4.73 |
42 | 51.70 | 50.80 | 50.30 | 49.80 | 4.34 | 4.58 | 4.70 | 4.82 |
47 | 57.10 | 56.00 | 55.50 | 55.00 | 4.42 | 4.67 | 4.79 | 4.91 |
52 | 60.40 | 59.30 | 58.70 | 58.10 | 4.46 | 4.71 | 4.84 | 4.96 |
57 | 63.70 | 62.50 | 61.90 | 61.30 | 4.51 | 4.76 | 4.88 | 5.01 |
62 | 67.00 | 65.70 | 65.10 | 64.50 | 4.55 | 4.81 | 4.93 | 5.06 |
67 | 70.30 | 69.00 | 68.30 | 67.70 | 4.60 | 4.85 | 4.98 | 5.11 |
72 | 73.60 | 72.20 | 71.50 | 70.80 | 4.64 | 4.90 | 5.03 | 5.16 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM.< /font> | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1750 | 0.99 | 0.98 |
2250 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | HSPF2 | |
1540 | 54500 | 3.60 | 35600 | 2.50 | 7.50 |
A.R.I. Standard Capacity Rating Conditions |
< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 05/08/2025 |
COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES
< font size="3"> OD AMB |
|
75 |
|
85 |
|
90 |
|
95 |
|
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM.< /font> | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1225 | 0.98 | 0.99 |
1575 | 1.02 | 1.01 |
ARI RATING FOR COOLING
CFM | CAPACITY (A) TEST | SEER2 | EER2 |
1540 | 41622 | 15.20 | 11.50 |
A.R.I. Standard Capacity Rating Conditions |
< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |
OD MODEL | ID MODEL | FURNACE | NOM CFM | ARI REF # |
Published Date: 05/08/2025 |
HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE
TOTAL CAPACITY MBH. | TOTAL POWER IN KILOWATTS | |||||||
OD AMB | 60 | 70 | 75 | 80 | 60 | 70 | 75 | 80 |
22 | 26.80 | 26.30 | 26.00 | 25.80 | 3.26 | 3.45 | 3.54 | 3.63 |
27 | 28.60 | 28.10 | 27.80 | 27.60 | 3.24 | 3.43 | 3.52 | 3.62 |
32 | 30.50 | 29.90 | 29.60 | 29.30 | 3.23 | 3.42 | 3.51 | 3.60 |
37 | 33.30 | 32.70 | 32.40 | 32.00 | 3.23 | 3.42 | 3.51 | 3.61 |
42 | 37.60 | 36.90 | 36.50 | 36.20 | 3.26 | 3.45 | 3.55 | 3.64 |
47 | 41.80 | 41.10 | 40.70 | 40.30 | 3.29 | 3.48 | 3.58 | 3.67 |
52 | 44.70 | 43.80 | 43.40 | 43.00 | 3.29 | 3.49 | 3.58 | 3.68 |
57 | 47.50 | 46.60 | 46.10 | 45.70 | 3.30 | 3.49 | 3.59 | 3.68 |
62 | 50.30 | 49.40 | 48.90 | 48.40 | 3.30 | 3.49 | 3.59 | 3.69 |
67 | 53.10 | 52.10 | 51.60 | 51.10 | 3.31 | 3.50 | 3.59 | 3.69 |
72 | 55.90 | 54.90 | 54.40 | 53.80 | 3.31 | 3.50 | 3.60 | 3.69 |
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW RATE, CFM.< /font> | CAPACITY MULTIPLIER | TOTAL POWER MULTIPLIER |
1225 | 0.99 | 0.98 |
1575 | 1.01 | 1.03 |
ARI RATING FOR HEATING
CFM | CAPACITY 47 | COP 47 | CAPACITY 17 | HSPF2 | |
1540 | 54500 | 3.60 | 35600 | 2.50 | 7.50 |
A.R.I. Standard Capacity Rating Conditions |
< font size="1">A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (C) Low Temperature Heating 17°F. D.B. ,15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. |